2).
Power range of direct current:
|
| |
This product is suitable for the
automobile storage battery of 12V/24V and the
automobile storage battery of 36V |
| |
|
| |
3). Frequency of recording data:
|
| |
The sampling cycle of the speed
is 0. 2 seconds, the sampling cycle of each state
is 0. 2 seconds, the time interval of the record
is once every second at present |
| |
|
| |
4). Monitoring the speed range 0-255km/h,
the resolution ratio is not more than 0. 1km/h. |
| |
|
| |
5). The measurement range of the
distance traveled is 0-99999. 9km, the resolution
ratio is not more than 0. 1km |
| |
|
| |
6). Record the state: |
| |
Regular 9 kinds: call out the stops,left
light,brake,loudspeaker right light,headlight
,atmospheric pressure,lighter,switch door (switch
door. Open 1 / close1; Open 2 / close 2); Reserve
5 kinds for other states |
| |
|
| |
7). The external dimension of driver’s
date recorders: 180X130X50mm (Built-in); 190X141X50mm(placed
outside) |
Performance
index |
DDR-600
driver’s data recorders |
Capacity of
the data memory |
byte
of 8M |
Voltage
of the standard power |
storage
battery of 12V |
ranging
between 9 and 16V |
maximal
voltage 24V |
storage
battery of 24V |
ranging
between 18 and 32V |
maximal
voltage 36V |
storage
battery of 36V |
ranging
between 27 and 48V |
maximal
voltage 54V |
consuming electric
current during dormancy |
<100mA |
Working temperature
Relative humidity
|
-20C~+70C
Can reach as high as 95% |
The standard
external dimension |
length
X width X highness is 180 mm X130 mm X50mm |
Interface
of the data |
USB disk |
Not
exceed 20s to read the data |
standard
USB interface |
Not
exceed 20s to read the data |
interface
of standard RS232C |
Upload
or download the data in alternative |
Serial
interface of TTL |
connect
with micro printer, Not exceed 30s to print
completely. |
The
interface of GPS is applied to the latter |
driver’s
IC card |
The
capacity of byte of 1K, is used in driver's
basic information to discern |